Journal of Vascular and Interventional Radiology
Volume 19, Issue 1 , Pages 42-46, January 2008

Spherical versus Conventional Polyvinyl Alcohol Particles for Uterine Artery Embolization

Department of Diagnostic Imaging, The Ottawa Hospital, University of Ottawa, 501 Smyth Road, Ottawa, Ontario, Canada, K1H 8L6.

Received 20 June 2007; received in revised form 17 August 2007; accepted 17 August 2007.

Purpose

To compare the efficacy of spherical polyvinyl alcohol (PVA) particles versus conventional PVA particles for uterine artery embolization (UAE).

Materials and Methods

Of 149 patients with 1-year follow-up after UAE, 96 received conventional PVA particles and 53 received spherical PVA particles. Severity of symptoms was ranked on an 11-point numeric rating scale (0–10). The changes in severity of symptoms after embolization, blood hemoglobin level, and the size of the dominant tumor depicted by ultrasonography were used to assess the efficacy of the two types of particles. The number of hysterectomies and myomectomies in each group was also recorded as evidence of UAE failure.

Results

On 1-year follow-up, patients treated with conventional PVA showed average numeric rating scale score improvements of 4.6 in menorrhagia, 2.9 in dysmenorrhea, 3.7 in pressure sensation, and 3.4 in urinary frequency. With spherical PVA, the average improvements were 3.0 in menorrhagia, 2.4 in dysmenorrhea, 3.1 in pressure sensation, and 2.0 in urinary frequency. Except in dysmenorrhea, all differences were significant (P < .001). With conventional PVA, there was an 8-mg/mL increase in blood hemoglobin level versus a 3-mg/mL increase with spherical PVA (P < .05). With conventional PVA, there was a 28-mm (34%) average reduction in diameter of the dominant tumor versus a 15.7-mm (19%) reduction with spherical PVA (P = .01). Eight of 96 patients (8%) treated with conventional PVA underwent hysterectomy or myomectomy during the entire length of the study, versus six of 53 patients (11%) treated with spherical PVA (P = .6). No patient underwent multiple embolizations.

Conclusions

In comparison with conventional PVA particles, UAE with the use of spherical PVA particles resulted in less fibroid tumor shrinkage and less improvement in clinical symptoms.

Abbreviations: PVA, polyvinyl alcohol, UAE, uterine artery embolization

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 None of the authors have identified a conflict of interest.